Toolhead breakout board with missing traces, plus hot end clean-up and heater test
A batch of Raise3D toolheads came in with burnt-on plastic and a breakout board that had lost traces at the fan connector. We cleaned and tested every hot end, rebuilt the broken traces, sealed them with UV-cured solder mask and put the toolheads back together.
The Raise3D E3G0750 toolhead breakout board, modelled from our photos. Switch between the board as it came in and after the repair. Drag to rotate, scroll or pinch to zoom.
| Machine | Raise3D 3D printer toolheads |
|---|---|
| Part | Toolhead breakout PCB (fan, heater and temperature connectors) |
| Fault | Missing PCB traces at the fan connector; plastic burnt onto the hot ends |
| Repair | Traces rebuilt, UV solder mask, hot ends cleaned, heaters tested |
| Tools | Thermal camera, bench power supply, soldering station, UV lamp |
| Result | Toolheads working again, no new board needed |
Send us a photo of the board or describe the fault. We repair PCB traces, connectors and toolheads for Raise3D, Creality, Prusa, Bambu and other printers.